Ser
No
TECHNICAL
SPECIFICATION
FOR
CONSTRUCTION
OF
OVERHEAD
ROOF
SHELTER
FOR
ASSEMBLY
GROUND
AT
ARMY
PUBLIC
SCHOOL
ASC
CENTRE
&
COLLEGE,
BANGALORE
1.
2
3
4.
5
6
15
7
Appendix
'A'
(Refer
Para
2
of
Part
IlIl
of
REP)
Nomenclature/Specification
of
the
Work
Fabrication
of
Over
Head
Shed
(Arch
Shaped).
Fabrication
and
fixing
/
framed
work,
including
cutting,
hoisting,
fixing
in
position
and
applying
priming
coat
of
approved
steel
primer
using
structural
steel
etc.
Foundation.
Earth
excavation
for
foundation
pillars
of
4'
x
4'
x5'
deep.
3'
x
3
footing
matt
of
12mm
and
8mm
TMT
bar
with
m25
grade
concrete.
Size
of
the
RCC
Pillars
2'
x
2'
x
6'
ISI approved
Vertical
Standing
with
Zigzag
Support.
Cold
Resistant
Mild
Steel
Electric
resistance
wielded
(ERWV)
or
High
frequency
induction
wielded
(HRIW)
Non
Rusted
square
pipe
of
high
tensile
strength
used
for
structural
triangular
vertical
truss
made
out
of
88mm
OD
12
gauge
and
60mm
OD
12
gauge
MS
tubes
of
20'
height
and
18"
x
18"
triangular
shaped
above
the
ground
level
as
per
design
and
drawing.
Supported
by
base
plate
of
10mm
thick
with
25mm
nut
and
bolt
anchoring
on
the
pedestal
pillars
and
further
concreting
using
m25
grade
concrete
for
base
support
against
heavy
winds
and
loads.
Vertical
poles
will
be
placed
both
the
sides
of
shed
at
the
distance
10'
ISI
Heavy
Duty
Triangular
Zigzag
Horizontal
Truss.
approved
Cold
Resistant
Mild
Steel
Electric
resistance
wielded
(ERW)
or
High
frequency
induction
wielded
(HRIW)
Non
Rusted
round
pipe
of
high
tensile
strength
used
for
structural
horizontal
truss
made
out
of
75mm
OD
12
gauge
and
48mm
OD
12
gauge
MS
tubes
as
per
design
and
drawing
resting
on
MS
plate
10mm
thick
20"
x
20"
of
vertical
poles
for
shorter
span
support
acting
as
load
bearing
and
load
distributor
duly
wielded
and
jointed
with
precise
condition.
Purlins
Along
Longer
Span.
ISl
approved
Cold
Resistant
Mild
Steel
Electric
resistance
wielded
(ERW)
or
High
frequency
induction
wielded
(HRIW))
Non
rusted
square
pipe
used
for
structural
purposes
of
size
cross
length
40mm X 40mm cross section 40mm of 2.Omm
tube
wall
thickness
14
gauge
pipe
as
per
drawing
and
design
for
longer
span
support
acting
as
load
distributor
along
the
way.
Butt
Plate
Joints.
All
the
joints
are
duly
fabricated
by
wielding
method
and
nut
bolt
mechanism
of
heavy
torque
high
tensile
strength
and
heavy
duty
members
06mm
thick
plates
are
used
of
12"
x
12"
square
shapes.
Paint.
Painting
of
all
the
mild
steel
structural
tubes
with
03
coat.
Remarks
Yes
No
upto
one
ft
above
the
ground
level.